Technical review: SKYLAB3D

EinScan Medixa for Orthotics and Prosthetics

Medixa clinic configuration at a glance
Item What is included or required
Capture and processing Standalone scanner with native onboard O&P software
Scanning computer Not required for onboard capture and processing
Model export STL, OBJ, and PLY; confirm the recipient's import requirements
Foot scanning accessory Foot Station 2 is a separate configuration item
Downstream design and fabrication Confirm software licenses and laboratory services separately

For an orthotics and prosthetics clinic, a useful 3D scan is one the design team can open, assess, and work from. Missing anatomy, an unclear patient position, or a file the fabrication partner cannot import can mean another appointment.

EinScan Medixa high-quality orthotics and prosthetics 3D scan results

EinScan Medixa brings scanning, processing, and an O&P-focused interface into one handheld device. Its included onboard software lets clinicians capture and review surface geometry without a separate scanning computer. This guide covers where it fits in a clinic, what the software includes, and how to evaluate the complete path from patient capture to a usable design file.

EinScan Medixa integration and workflow customization options

Where Medixa fits in an O&P clinic

The scanner has presets for cranial and facial capture, the torso, upper and lower limbs, feet, sockets, seating, and foam boxes. Choose the preset around the intended deliverable, then agree on the capture conditions with the person who will modify or fabricate from that scan.

Questions to settle before the first production scan
Application Capture focus Agree with the design or fabrication team
Limb and socket workflows The relevant limb surface or an existing socket Required coverage, landmarks, limb position, and how the scan will be modified
Torso and cranial workflows Body-region geometry and any required surface markings Positioning protocol, boundaries, and whether the receiving software needs texture
Foot and ankle workflows Foot geometry using the dedicated foot-scanning setup Foot Station 2 configuration, capture conditions, and sole coverage
Seating and foam-box workflows The selected seating surface or impression geometry Which contours must remain intact during trimming and export

These are capture workflows, not automatic device-design prescriptions. Clinical assessment, corrective design, fabrication, and fitting remain separate responsibilities. A clean mesh alone does not establish that an orthosis or prosthesis will fit as intended.

Included O&P software, without a scanning workstation

Medixa includes its native onboard O&P software for scanning, processing, editing, measurement, and export. SKYLAB3D's current configuration does not require a separate license or ongoing subscription for that native workflow. EXModel and Inspect are not included or required for standard onboard operation.

EinScan Medixa all-in-one wireless scanning and onboard processing

The integrated screen lets the operator inspect the capture before moving on. The documented measurement tools include a bounding box and point-to-point distance. A geodesic option measures distance along a connected surface; it is not the same measurement as a straight line between two points.

Medixa interface sequence showing preset selection, scanning, alignment, and data export
The onboard sequence takes the operator from a scan preset to an exportable model.

Ask separately about any downstream O&P design platform, laboratory service, or manufacturing system. Being able to export a mesh does not include the receiving software's license, a fabricated device, or clinical design services.

Review the capture while the patient is still available

Prepare a stable, comfortable position under the clinic's protocol. Hair and clothing can obscure the intended surface. Movement compensation is intended to help with slight motion; it does not remove the need to manage patient position or inspect the result.

  1. Start with the relevant preset. Confirm the scan region and required output before changing resolution or alignment settings.
  2. Watch coverage during capture. Follow the intended surface rather than assuming a single pass has recorded every contour.
  3. Rotate and inspect the result. The scanning interface allows review of missing areas and continued capture. Resolve important gaps before ending the session.
  4. Keep editing traceable. Remove unwanted background carefully. Where hole filling creates a surface, do not mistake it for anatomy that was actually captured. Retain the original when the clinic's record policy requires it.

If the lab relies on skin markings, demonstrate texture capture and verify that those markings survive the chosen export and import path. Appearance on the scanner screen is only the first check.

Foot Station 2 is a separate configuration decision

The dedicated feet-scanning procedure uses a bound Foot Station 2. It supports single-foot or both-feet capture. The documented Insole-SMO mode covers the sole to the ankle, while AFO-KAFO extends from the sole toward the thigh.

Operator scanning a foot on Foot Station 2 with EinScan Medixa and viewing capture on its integrated screen
Foot Station 2 provides the dedicated setup for foot capture. The scanner is purchased and configured separately.

During a demonstration, check that the station markers remain visible and that the sole is complete. The manufacturer's procedure cautions against strong overhead direct light. Have the clinician define the appropriate positioning and loading conditions for the intended device.

Review Foot Station 2 compatibility and configuration alongside the scanner. It is an accessory, not a standalone scanner, and should appear as a separate item unless the selected package explicitly includes it.

Export files and Mac access

Medixa exports STL, OBJ, and PLY files. Its documented sharing options include riiForm, BabySymmetry, and Protosthetics, with supported formats varying by platform. Confirm the exact import requirements and account access with your receiving team before committing to a workflow.

Scanning runs on the device itself. For USB-C file transfer, Windows supports direct access through the system file manager. On a Mac, the manufacturer instructs users to install third-party transfer software such as OpenMTP. That is a transfer requirement, not a statement that a desktop scanning application runs on macOS.

Activate the device before the first export; unactivated devices cannot upload or export projects. For the handoff test, open a representative file in the actual destination software and confirm scale, orientation, visible landmarks, and any required texture. Send the capture position and relevant project notes through the clinic's approved record process.

Before using any cloud-sharing route for patient data, have the clinic's privacy and IT leads approve it. HHS guidance calls for appropriate risk analysis and business associate arrangements when a HIPAA-regulated organization uses a cloud provider to handle electronic protected health information. A sharing feature by itself does not establish compliance.

What to bring to a SKYLAB3D demonstration

A useful evaluation ends with an accepted file, not just a successful scan on screen. Bring a representative, appropriately authorized test case and the receiving team's requirements.

  • Your common application: Identify the body region, existing device, or impression you capture most often.
  • Acceptance criteria: Specify the contours, landmarks, and measurements the recipient needs, including when a rescan would be required.
  • The destination: Name the design software, version, and fabrication partner. Test the import rather than relying on a format label.
  • A repeat scan: Check consistency under your expected operator and positioning conditions.
  • Total handling time: Include setup, capture, review, editing, and transfer when comparing the workflow with your current process.
  • Implementation needs: Include accessories, onboarding, and any downstream licenses in the purchase review. On-site training fees are quoted plus travel expenses.

For general human-shape capture in workplace or product development, our EinScan H2 ergonomic body-scanning guide covers that different application. Medixa's O&P presets and standalone operation are the focus here.

Ready to review the configuration? Request a Medixa quote from SKYLAB3D with the accessories, training, and file-delivery requirements your clinic needs.

Technical references

Manufacturer documentation and clinical data-handling guidance:

Scanners discussed in this guide

Frequently asked questions

Does EinScan Medixa include scanning software?

Yes. Medixa includes its native onboard O&P software for capture, processing, editing, measurement, and export. SKYLAB3D's current native-workflow configuration does not require a separate software license or ongoing subscription. Downstream design software and fabrication services are separate.

Do I need a PC or a Mac to scan with Medixa?

No external computer is required for onboard scanning and processing. For USB-C export, Windows supports direct file-manager access. Mac users need third-party file-transfer software such as OpenMTP, according to the manufacturer's instructions. Check the requirements of your downstream design software separately.

Is Foot Station 2 included with the scanner?

Treat Foot Station 2 as a separate accessory unless your selected package expressly includes it. The dedicated feet-scanning procedure uses a bound station. Confirm the complete configuration on the quote.

Does a Medixa scan produce a finished orthosis or prosthesis?

No. It produces surface geometry for an O&P workflow. Clinical assessment, design modification, fabrication, and fitting remain separate steps. Evaluate the exported scan in the software and process your clinic actually uses.