EinScan Trak
$6,999.00
View EinScan Trak
A vehicle frame can be scanned for two very different reasons: to reconstruct its geometry for a modification, or to decide whether its dimensions meet a drawing. Both jobs need reliable data. The second also needs a defensible measurement and acceptance process.
EinScan Trak and FreeScan Trak ProW+ both use an external optical tracker to locate the scanner without covering the workpiece in tracking stickers. They serve different buying priorities. Start with EinScan Trak for flexible large-part capture and scan-to-CAD work; evaluate FreeScan Trak ProW+ when large-volume dimensional inspection is the main requirement. Neither choice removes the need to verify critical features on the actual part.

For a retrofit, a usable mesh and reconstructed CAD may be the deliverables. For production inspection, the deliverable could be a datum-aligned evaluation, characteristic results, and a release report. A dense mesh is an input to either workflow, not proof that both workflows have been completed.
| Decision | EinScan Trak | FreeScan Trak ProW+ |
|---|---|---|
| Primary fit | Professional digitization, reverse engineering, and automotive customization. | Optically tracked metrology and large-part dimensional inspection. It can also supply reverse-engineering data. |
| Tracked working volume | Up to 15 m3. | Up to 156 m3 at one station; up to 8.6 m tracking distance. |
| Published measurement specifications | Volumetric accuracy stated as up to 0.1 mm. | Accuracy stated as 0.023 mm. Volumetric accuracy is specified separately by volume: 0.046 mm at 12 m3, rising to 0.156 mm at 156 m3. |
| Access strategy | Detach the scanner for handheld capture where tracker access is difficult. Marker-free handheld capture depends on suitable surface features. | Plan tracked scanner access and station changes. Optional compatible FreeProbe equipment can measure selected features by contact. |
| Capture and analysis software | EXScan Trak capture software and a complimentary one-year EXMeasure license. CAD reconstruction software such as EXModel is a separate option. | Included FreeScan Trak capture software with an integrated inspection module. SHINING3D Inspect and CAD reconstruction software such as EXModel Pro are separate license options; confirm the required functions and terms in the quotation. |
The figures above are published system specifications, not uncertainty estimates for your complete process. The two volumetric figures are not a like-for-like laboratory comparison at an identical working volume. A larger tracking envelope does not guarantee access to every face of an assembly.
The tracker sees targets built into the scanner rather than stickers distributed across the workpiece. This can remove a substantial preparation step, especially on broad, low-feature surfaces. It does not mean every capture mode, station transition, or photogrammetry procedure is free of reference hardware.
With EinScan Trak, tracked capture and detached handheld capture use different positioning approaches. Feature-rich geometry can support marker-free handheld operation, while repetitive or low-feature areas may need markers or another controlled alignment strategy. For detailed station planning, see the EinScan Trak large-part reverse-engineering workflow.
ProW+ includes video photogrammetry, or VPG. Shining 3D describes removal of the need for coded markers, using a calibration rod and real-time marker verification. Do not interpret that statement as eliminating every marker or scale reference from every extended-volume procedure.
Both systems need suitable lines of sight between the tracker and the scanner in tracked operation. Ribs, fixtures, machinery, and the operator can obstruct the view. Moving a station also requires a controlled connection to the existing coordinate system. Plan these transitions before comparing the preparation time saved.
For CAD reconstruction, evaluate whether the captured surfaces and independently checked interfaces support the design task. For dimensional inspection, additionally define the measurands, datum construction, alignment, feature extraction, uncertainty, and acceptance criteria. Smoothing, hole filling, or an unconstrained best-fit alignment can conceal the deviation you intended to evaluate.
The ProW+ manufacturer lists acceptance testing based on VDI/VDE 2634 and ISO 10360, with calibration in an ISO/IEC 17025-accredited laboratory. Obtain the applicable test documentation and scope for the quoted configuration. Those statements do not certify every operator, workpiece, shop-floor condition, or customer release procedure.
NIST's metrological-traceability guidance treats traceability as a property of a measurement result supported by a documented calibration chain. Traceability alone does not establish fitness for the required tolerance. In a U.S. quality workflow, the uncertainty and evidence must satisfy the actual measurement need and customer requirements.
Keep contact measurement or another validated method for inaccessible bores, hidden interfaces, or characteristics the optical workflow cannot adequately resolve. FreeProbe is an optional probing accessory, not a second scanner, and its compatibility and supplied configuration must be confirmed. SKYLAB3D's industrial 3D scanning inspection guide provides the broader application-selection path.
Use representative work, including the finish and access conditions that cause trouble in production. A convenient demonstration object will not reveal the cost of cleaning a casting, reaching behind a fixture, or recovering a lost tracking view.
ProW+ offers 93 crossed laser lines for high-speed scanning, 25 parallel lines for detail, and a single line for deep pockets, with a stated maximum acquisition rate of 7.6 million points per second. These are capture specifications, not the time needed to deliver checked CAD or an accepted inspection report. Use the representative-part trial to choose modes and point spacing around the required features.
A practical cost calculation uses your measured labor time, loaded hourly rate, consumables, and repeat-work frequency. Add software, training, support, and deployment costs. Do not credit the scanner with downtime savings until your trial shows that production actually resumes sooner.
EinScan Trak at SKYLAB3D is the relevant starting point when a flexible tracked-and-handheld capture workflow supports large-object CAD work. FreeScan Trak ProW+ at SKYLAB3D deserves evaluation when the larger tracked envelope and metrology documentation address an inspection requirement. Tighter measurement needs can also justify a metrology system for reverse engineering; the labels are buying priorities, not prohibitions.
FreeScan Trak ProW+ is a distinct upgraded model, not another spelling of FreeScan Trak ProW. Specify the exact variant when reviewing a demonstration or quotation. Compare the complete configuration, including analysis licenses and any probing accessories, with other Shining 3D industrial scanning systems.
SKYLAB3D's ProW+ catalog figure is budgetary, not a final configured system offer. Confirm the current U.S. system price, packing list, software licenses, workstation, probing equipment, training, warranty, and delivery in the formal quotation. A workstation, FreeProbe, extra software, and training are optional unless expressly included.
If large-part CAD capture is your immediate task, request an EinScan Trak reverse-engineering demo using a representative part and the deliverable you need.
$6,999.00
View EinScan Trak$135,000.00
View FreeScan Trak ProW+Not automatically. EinScan Trak is a professional tracked-and-handheld capture system suited to digitization and reverse engineering. FreeScan Trak ProW+ targets optically tracked metrology over a larger volume. Select and validate the complete process against the required CAD or inspection deliverable.
No. Tracked capture follows targets on the scanner rather than stickers across the workpiece. Other capture modes, station transitions, and global-reference procedures may still need markers or reference artifacts. ProW+ VPG removes the need for coded markers, not every reference in every procedure.
No. Point spacing describes sampling density, not the error or uncertainty of a measurement result. Evaluate the complete measurement process, including scale, alignment, feature extraction, environment, and comparison with an appropriate reference.
No. ProW+ is an upgraded model with its own specifications. Keep the exact variant name on the demonstration plan and quotation; do not transfer price, accessories, or performance specifications from the older ProW without confirmation.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}